CONTACTOR AX12-30-10 220-230V 50HZ ABB

SKU
1SBL911074R8010PEAN
3471522393807Garantía
6 meses
Stock alto
Descripción
Dimensiones
44 mm
74 mm
74 mm
0.326 kg
Technical
3
0
1
0
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors T = 40 °C 26 A
acc. to IEC 60947-5-1, T = 40 °C 16 A
(220 / 240 V) 55 °C 22 A
(690 V) 40 °C 25 A
(690 V) 70 °C 18 A
(415 V) 55 °C 12 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A
(380 / 400 V) 55 °C 12 A
(220 / 230 / 240 V) 55 °C 12 A
(500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
(24 V) 6 A / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
(415 V) 5.5 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
for 0.1 s 140 A
for 1 s 100 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Auxiliary Circuit 6 kV
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
3600 cycles per hour
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions AC-1 per Pole 0.8 W
at Rated Operating Conditions AC-3 per Pole 0.1 W
Between Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Auxiliary Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Screw Terminals
Block Contactor
Technical UL/CSA
(600 V AC) 25 A
(120 V AC) Single Phase 3/4 hp
(200 ... 208 V AC) Three Phase 3 hp
(220 ... 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 ... 480 V AC) Three Phase 7.5 hp
(550 ... 600 V AC) Three Phase 10 hp
Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb
(120 V AC) Single Phase 13.8 A
(200 ... 208 V AC) Three Phase 11 A
(220 ... 240 V AC) Three Phase 9.6 A
(240 V AC) Single Phase 12 A
(440 ... 480 V AC) Three Phase 11 A
(550 ... 600 V AC) Three Phase 11 A
Ambiente
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Without Derating 3000 m
Material Compliance
CMRT - Conflict Minerals Reporting Template
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act (TSCA) declaration for Contactors
Business To Business
Certificados y Declaraciones (Número de Documento)
AX 06~25A CB certification
9AKK107492A7089
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Información de Embalaje
box 1 piece
48 mm
78 mm
79 mm
0.34 kg
3471522393807
30 piece
240 mm
295 mm
145 mm
10.2 kg
Clasificaciones y estándares externos
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors
3707314
- Ancho del product:
44 mm
- Largo del product:
74 mm
- Alto del producto:
74 mm
- Peso del product:
0.326 kg
Technical
- Número de contactos principales NO:
3
- Número de contactos principales NC:
0
- Número de contactos auxiliares NO:
1
- Número de contactos auxiliares NC:
0
- Tensión nominal de operación:
Auxiliary Circuit 690 V
Main Circuit 690 V
- Frecuencia nominal (f):
Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
- Corriente térmica convencional de aire libre (Ith):
acc. to IEC 60947-4-1, Open Contactors T = 40 °C 26 A
acc. to IEC 60947-5-1, T = 40 °C 16 A
- Corriente nominal de funcionamiento AC-1 (Ie):
(220 / 240 V) 55 °C 22 A
(690 V) 40 °C 25 A
(690 V) 70 °C 18 A
- Corriente nominal de funcionamiento AC-3 (Ie):
(415 V) 55 °C 12 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A
(380 / 400 V) 55 °C 12 A
(220 / 230 / 240 V) 55 °C 12 A
- Corriente nominal de funcionamiento AC-15 (Ie):
(500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
- Corriente nominal de funcionamiento DC-13 (Ie):
(24 V) 6 A / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
- Potencia operativa nominal AC-3 (Pe):
(415 V) 5.5 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
- Corriente nominal de corta duración Tensión baja (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
for 0.1 s 140 A
for 1 s 100 A
- Capacidad de rotura máxima:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Tensión nominal de aislamiento (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Tensión nominal soportada por impulsos (Uimp):
Auxiliary Circuit 6 kV
- Frecuencia máxima de conmutación eléctrica:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
- Frecuencia máxima de conmutación mecánica:
3600 cycles per hour
- Tensión nominal del circuito de control (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
- Pérdida de potencia:
at Rated Operating Conditions AC-1 per Pole 0.8 W
at Rated Operating Conditions AC-3 per Pole 0.1 W
- Tiempo de funcionamiento:
Between Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
- Grado de protección:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Par de apriete:
Auxiliary Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
- Tipo de terminal:
Screw Terminals
- Nombre del producto:
Block Contactor
Technical UL/CSA
- Clasificación de uso general UL/CSA:
(600 V AC) 25 A
- Potencia nominal UL/CSA:
(120 V AC) Single Phase 3/4 hp
(200 ... 208 V AC) Three Phase 3 hp
(220 ... 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 ... 480 V AC) Three Phase 7.5 hp
(550 ... 600 V AC) Three Phase 10 hp
- Par de apriete UL/CSA:
Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb
- Amperios a plena carga Uso del motor:
(120 V AC) Single Phase 13.8 A
(200 ... 208 V AC) Three Phase 11 A
(220 ... 240 V AC) Three Phase 9.6 A
(240 V AC) Single Phase 12 A
(440 ... 480 V AC) Three Phase 11 A
(550 ... 600 V AC) Three Phase 11 A
Ambiente
- Temperatura ambiente:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
- Resistencia climática:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Altitud máxima de funcionamiento permisible:
Without Derating 3000 m
Material Compliance
- Plantilla de notificación de minerales de conflicto (CMRT):
CMRT - Conflict Minerals Reporting Template
- Declaración REACH:
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
- Información sobre RoHS:
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
- Estado de RoHS:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Ley de Control de Sustancias Tóxicas - TSCA:
Toxic Substances Control Act (TSCA) declaration for Contactors
- WEEE B2C / B2B:
Business To Business
- Categoría RAEE:
- Small Equipment (No External Dimension More Than 50 cm)
Certificados y Declaraciones (Número de Documento)
- Certificado CB:
AX 06~25A CB certification
- Certificado CCC:
9AKK107492A7089
- Certificado CCS:
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
- Certificado CQC:
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
- Declaración de conformidad - CCC:
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
- Declaración de conformidad - CE:
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
- Certificado UL:
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Información de Embalaje
- Embalaje Nivel 1 Unidades:
box 1 piece
- Embalaje Nivel 1 Ancho:
48 mm
- Embalaje Nivel 1 Largo:
78 mm
- Embalaje Nivel 1 Alto:
79 mm
- Embalaje Nivel 1 Peso:
0.34 kg
- Embalaje Nivel 1 EAN:
3471522393807
- Embalaje Nivel 2 Unidades:
30 piece
- Embalaje Nivel 2 Ancho:
240 mm
- Embalaje Nivel 2 Largo:
295 mm
- Embalaje Nivel 2 Alto:
145 mm
- Embalaje Nivel 2 Peso:
10.2 kg
Clasificaciones y estándares externos
- Código de clasificación de objetos:
Q
- ETIM 7:
EC000066 - Power contactor, AC switching
- ETIM 8:
EC000066 - Power contactor, AC switching
- ETIM 9:
EC000066 - Power contactor, AC switching
- Clase electrónica:
V11.0 : 27371003
- UNSPSC:
39121529
- Código de categoría granular de IDEA (IGCC):
4755 >> Contactors